Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS303LEAA0AAAA — OEM 1171554 | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS303LEAA0AAAA — OEM 1171554 | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp definite purpose contactor (part #1171554) with a 24-volt coil switches line power to the compressor and condenser fan on ICP/Tempstar/Heil RGS303LEAA0AAAA equipment. When the thermostat calls, the 24V coil pulls in the contacts to energize the load. Contactors wear out from arcing — pitted or welded contacts, a chattering or buzzing coil, or burnt terminals are all signs of failure. A failed contactor can leave the system dead or, worse, stick closed and run the compressor continuously. This direct-fit replacement restores reliable, safe switching.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amp
Coil Voltage 24V
Brand ICP (Tempstar / Heil)
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RGS303LEAA0AAAA and other ICP-family units specifying part 1171554. Confirm pole count, amp rating, and 24V coil voltage match your original contactor.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical access panel.
  3. Document — Photograph every line, load, and coil wire on the old contactor.
  4. Remove — Move wires one at a time to the new contactor, or label and remove them, then unscrew the old contactor.
  5. Install — Mount the new 30A 2-pole contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the coil pulls in and the contacts energize the load cleanly.

Signs You Need a Replacement

  • Pitted, burnt, or welded contacts
  • Buzzing or chattering coil
  • Compressor or condenser fan won't start
  • Contacts stick closed and the unit won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS303LEAA0AAAA — OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS303LEAA0AAAA — OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS303LEAA0AAAA — OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online