This is a genuine OEM 2-pole, 30-amp contactor with a 24-volt coil for the ICP / Tempstar / Heil RGS300STEA0AAAA, ICP part number 1171554. The contactor is the high-current switch that energizes the compressor and condenser fan whenever the thermostat calls for cooling. The 24VAC coil pulls the contacts closed, passing line voltage to the load; when the call ends, the contacts open and stop the unit. Contactors are mechanical wear items — their contacts pit, arc, and eventually weld or fail to close. A worn contactor causes hard starts, chatter, or a unit that will not run at all, and welded contacts can leave the compressor running with no way to shut off.

Specifications

Spec Value
Part Number 1171554
Type Definite-Purpose Contactor
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2 (Double-Pole)
Fitment OEM Direct Replacement

Compatibility

A direct OEM replacement for ICP, Tempstar, Heil, and Comfortmaker units on the RGS300 platform, including model RGS300STEA0AAAA. Confirm a 2-pole, 30A frame with a 24V coil and ICP part 1171554 before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control-box service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect line, load, and 24V coil leads per your photo.
  6. Test — Restore power and verify the contactor pulls in on a cooling call and the compressor energizes.

Signs You Need a Replacement

  • Loud chatter or buzzing from the contactor.
  • Pitted, blackened, or welded contacts.
  • Compressor will not start, or will not shut off.
  • Visible arcing or a burnt-plastic smell at the contactor.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS300STEA0AAAA — OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS300STEA0AAAA — OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS300STEA0AAAA — OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online