This genuine OEM 2-pole definite-purpose contactor, ICP part number 1171554, is rated 30 amps with a 24-volt control coil for use in ICP, Tempstar, and Heil systems. The contactor is the high-voltage switch that powers the compressor and outdoor fan: when the thermostat calls for cooling, 24V energizes the coil, pulling the contacts closed to feed line voltage to the condensing unit. A worn contactor is one of the most common HVAC failures — pitted or welded contacts cause hard starting, chatter, or a unit that won't run at all.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2 (Double-Pole)
Contact Rating 30 Amps
Coil Voltage 24V
Fitment OEM Direct Replacement

Compatibility

Direct-fit OEM replacement for the ICP / Tempstar / Heil RGS300SFEA0AAAA and other RGS-family units that originally shipped with part 1171554. Verify pole count, amp, and coil voltage against your old part before installing.

Installation Guide

  1. Safety First – Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access – Remove the condensing unit electrical access panel.
  3. Document – Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove – Label and transfer wires one at a time, then unscrew the old contactor from the base.
  5. Install – Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test – Restore power and call for cooling; confirm the contacts pull in cleanly and the compressor and fan energize.

Signs You Need a Replacement

  • Compressor/condenser won't start or starts intermittently
  • Buzzing, humming, or chattering at the contactor
  • Visibly pitted, burnt, or welded contacts
  • Coil energizes but contacts fail to close

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS300SFEA0AAAA – Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS300SFEA0AAAA – Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS300SFEA0AAAA – Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online