Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS243LEEA0AAAA — OEM | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS243LEEA0AAAA — OEM | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-Pole 30 Amp Contactor (part number 1171554) is the electromechanical switch that powers high-voltage loads on the ICP RGS243LEEA0AAAA system. A 24V signal from the control board energizes the coil, pulling the contacts closed to deliver line voltage to the connected load. Contactors are high-cycle wear items: their contacts pit, burn, and weld over time, while the coil can fail open. Symptoms include a system that won't start, chattering or buzzing at the contactor, or a unit that runs continuously because the contacts have welded shut. Replacing with the genuine OEM 30A, 2-pole, 24V-coil contactor restores clean, reliable switching.

Specifications

Spec Value
Part Number 1171554
Type 2-Pole Contactor
Brand ICP / Heil / Tempstar / Comfortmaker
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Fitment OEM replacement

Compatibility

Direct OEM replacement contactor for the ICP RGS243LEEA0AAAA and related Heil, Tempstar, and Comfortmaker units using a 2-pole, 30A, 24V-coil contactor. Confirm your existing contactor is rated 30A with a 24V coil and stamped 1171554 before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Label and disconnect the wires, unfasten the mounting screws, and lift out the old contactor.
  5. Install — Mount the new 1171554 contactor and reconnect every wire exactly per your photos.
  6. Test — Restore power, place a call for operation, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • System won't start even though the control board sends 24V to the coil.
  • Loud buzzing, chattering, or humming at the contactor.
  • Burned, pitted, or welded contacts; unit runs nonstop.
  • Visible arcing, melting, or heat discoloration on the terminals.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS243LEEA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS243LEEA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS243LEEA0AAAA — OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera