Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS240STEA0AAAA — OEM 1171554 | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS240STEA0AAAA — OEM 1171554 | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The 1171554 contactor is the OEM 2-pole, 30-amp, 24-volt definite-purpose contactor for the ICP Tempstar / Heil RGS240STEA0AAAA system. The contactor is an electrically operated switch: when the thermostat calls and the 24V coil energizes, the contacts close to deliver line voltage to the compressor and condenser fan motor. Over time the contacts pit and burn from arcing, and the coil can fail open or chatter. Symptoms include a unit that won't start, a buzzing or chattering contactor, or compressor and fan that fail to engage. This OEM 30A 2-pole replacement restores clean, reliable switching.

Specifications

Spec Value
Part Number 1171554
Type Definite-Purpose Contactor, 2-Pole
Brand ICP (Tempstar / Heil)
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Fitment OEM Direct Replacement

Compatibility

This 2-pole 30A 24V contactor is the OEM replacement for the ICP Tempstar Heil RGS240STEA0AAAA and related RGS240-series units across the ICP brand family (Heil, Tempstar, Comfortmaker, Arcoaire). Confirm pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer wires one at a time or label them, unfasten the old contactor, and remove it.
  5. Install — Mount the new 1171554 contactor and reconnect each wire to the matching terminal per your photos.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor/fan energize.

Signs You Need a Replacement

  • Loud buzzing or chattering from the contactor
  • Pitted, burnt, or welded contacts
  • Compressor and condenser fan fail to start on a call
  • Coil reads open or out of spec on the multimeter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240STEA0AAAA — OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240STEA0AAAA — OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240STEA0AAAA — OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online