Overview

The OEM 2-pole, 30-amp definite purpose contactor (part #1171554) with a 24V coil is the primary switching relay for the ICP Tempstar Heil RGS240LDFA0AAAA system. When the thermostat calls, the 24V coil pulls the contacts closed to send line voltage to the compressor and condenser fan motor. Pitted, burned, or chattering contacts cause hard starts, no-cool conditions, buzzing, or a unit that won't shut off. This genuine OEM contactor restores clean, reliable switching.

Specifications

Spec Value
Part Number 1171554
Description Contactor 2P 30A 24V
Type 2-Pole Definite Purpose Contactor
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Brand ICP / Tempstar / Heil
Fits Model RGS240LDFA0AAAA
Fit OEM Direct Replacement

Compatibility

This 2-pole 30A 24V contactor is a direct-fit replacement for ICP, Tempstar, Heil, Comfortmaker, and Arcoaire-family model RGS240LDFA0AAAA. Verify pole count, contact amperage, and 24V coil rating against your existing contactor.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical access panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or label each lead, then unfasten and remove the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and energizes the compressor and fan.

Signs You Need a Replacement

  • Loud buzzing or chattering from the contactor
  • Pitted, burned, or welded contacts
  • Compressor/condenser fan won't start or won't stop
  • Intermittent or no-cool operation

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240LDFA0AAAA — OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240LDFA0AAAA — OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240LDFA0AAAA — OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online