Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS210SSCA0AAAA — Definite Purpose | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS210SSCA0AAAA — Definite Purpose | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM definite purpose contactor, ICP part number 1171554, is a 2-pole, 30-amp device with a 24-volt coil used to switch the compressor and condenser fan in ICP, Heil, and Tempstar cooling equipment. When the thermostat calls for cooling, the 24V control signal energizes the coil, pulling the contacts closed to deliver line voltage to the compressor and fan motor. Contactors are a high-wear part: their contacts arc every cycle and eventually pit, burn, or weld. A failing contactor is one of the most common causes of an outdoor unit that hums but won't start, or one that won't shut off when the call ends.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Contact Rating 30 A
Coil Voltage 24 VAC
Poles 2

Compatibility

Factory replacement for ICP-family equipment including model RGS210SSCA0AAAA. As a standard 2-pole, 30A, 24V coil definite purpose contactor, it also services many comparable Heil, Tempstar, Comfortmaker, and Arcoaire condensing units. Confirm pole count, amp rating, and 24V coil before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to reach the contactor.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Label and remove the spade and lug connections, then unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and drops out cleanly when satisfied.

Signs You Need a Replacement

  • Outdoor unit hums but compressor/fan won't start
  • Pitted, blackened, or welded contacts
  • Buzzing or chattering from the contactor
  • Compressor won't shut off after the call ends

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS210SSCA0AAAA — Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS210SSCA0AAAA — Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS210SSCA0AAAA — Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online