Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS210SEAA0AAAA — 30 Amp | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS210SEAA0AAAA — 30 Amp | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 2-pole, 30-amp contactor with a 24-volt coil (part 1171554) is the switching relay for the ICP Tempstar Heil RGS210SEAA0AAAA. When the thermostat calls and the 24V coil energizes, the contactor's two poles close to deliver line voltage to the compressor and condenser fan. Contactors are high-wear parts: their contacts arc on every cycle and eventually pit, weld, or fail open. A bad contactor is one of the most common reasons a unit hums but won't start, won't shut off, or trips on every call. Replacing this 30A 2-pole contactor restores clean, reliable switching.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amp
Coil Voltage 24V
Brand ICP / Heil / Tempstar
Fit OEM Replacement

Compatibility

Fits the ICP RGS210SEAA0AAAA and the broad range of ICP, Heil, Tempstar, and Comfortmaker systems that use a 2-pole 30A definite-purpose contactor with a 24V coil. Verify pole count, amperage, and coil voltage against your old part.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical access/service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time from the old contactor, or unscrew and lift it from its rail.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the unit starts.

Signs You Need a Replacement

  • Unit hums or buzzes but the compressor won't start
  • Pitted, burned, or welded contacts
  • System won't shut off when the call ends
  • Chattering contactor or repeated breaker trips

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS210SEAA0AAAA — 30 Amp | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS210SEAA0AAAA — 30 Amp | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS210SEAA0AAAA — 30 Amp | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online