Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS150LTCA0AAAA — OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS150LTCA0AAAA — OEM 1178074 | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 2-pole, 30-amp contactor with a 24-volt coil (part number 1178074) for the ICP / Tempstar / Heil RGS150LTCA0AAAA. The contactor is the high-voltage switch that the 24V thermostat circuit energizes to power the compressor and outdoor fan motor on a cooling call. As the coil pulls in, the contacts close and pass line voltage to the load. Pitted or welded contacts, a chattering or burned-out coil, and insect-fouled poles are common failure modes that cause no-cooling, a unit that won't start or shut off, or buzzing at the contactor.

Specifications

Spec Value
Part Number 1178074
Type Definite-purpose contactor, 2-pole
Contact Rating 30 Amp
Coil Voltage 24V
Poles 2
Brand ICP (Tempstar / Heil / Comfortmaker)
Fits Model RGS150LTCA0AAAA
Fitment OEM replacement

Compatibility

Fits the ICP-family RGS150LTCA0AAAA and the shared RGS150 platform sold as Tempstar, Heil, and Comfortmaker. Confirm a 2-pole, 30A, 24V-coil contactor and OEM number 1178074 against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit and breaker; verify zero voltage across the contactor terminals with a multimeter.
  2. Access — Remove the electrical service panel to expose the contactor.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Unscrew the old contactor from the bracket and transfer wires one at a time to avoid mix-ups.
  5. Install — Mount the new 2-pole contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan energize.

Signs You Need a Replacement

  • Outdoor unit won't start, or won't shut off, on a cooling call
  • Loud buzzing, humming, or chattering at the contactor
  • Pitted, burned, or welded-together contacts
  • 24V coil that no longer pulls the contacts in

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150LTCA0AAAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150LTCA0AAAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150LTCA0AAAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online