ICP 2-Pole 30A 24V Contactor for RGS121STAA0AAAA — 30 Amp | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS121STAA0AAAA — 30 Amp | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM ICP 2-pole, 30-amp contactor with a 24-volt coil, part number 1178074, for the RGS121STAA0AAAA system. The contactor is an electrically controlled switch: when the 24V coil energizes on a call from the control board, it pulls in two sets of line-voltage contacts to power the connected load. A contactor lives a hard life of constant make/break cycles, so its contacts eventually pit, burn, or weld. Symptoms of failure include a unit that won't start, a humming or chattering contactor, contacts that stay stuck closed so the load runs continuously, or visibly burnt and corroded terminals. Replacing a worn contactor restores reliable switching and protects downstream components.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V AC
Fit OEM Replacement
Compatible Model RGS121STAA0AAAA

Compatibility

Fits the ICP/Tempstar/Heil RGS121STAA0AAAA and other ICP-family units specifying a 2-pole 30A contactor with a 24V coil. Match poles, amp rating, and coil voltage to your original before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical/service panel to reach the contactor.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time or label each, then unscrew the old contactor from its base.
  5. Install — Mount the new 1178074 contactor and reconnect every wire per your photo, torquing terminals snug.
  6. Test — Restore power and confirm the contactor pulls in cleanly and the load starts and stops on demand.

Signs You Need a Replacement

  • Unit won't start or starts intermittently.
  • Loud humming or chattering from the contactor.
  • Contacts stuck closed so the load runs nonstop.
  • Burnt, pitted, or corroded contacts and terminals.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121STAA0AAAA — 30 Amp | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121STAA0AAAA — 30 Amp | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121STAA0AAAA — 30 Amp | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online