Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS121SFCA0AAA — OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS121SFCA0AAA — OEM 1178074 | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 2-pole definite-purpose contactor (part number 1178074) is rated 30 amps with a 24-volt coil and is the direct replacement switching relay for the ICP / Tempstar / Heil RGS121SFCA0AAA system. The contactor is energized by the 24V control circuit and closes its line-voltage contacts to power the compressor and condenser fan motor. Contactors are one of the most common HVAC failure points: the coil burns out, or the silver contacts pit and weld from arcing over thousands of cycles. Symptoms include a unit that won't start, chattering/buzzing at the contactor, or a system that runs continuously because the contacts have welded shut.

Specifications

Spec Value
Part Number 1178074
Type 2-Pole Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2
Fitment OEM direct replacement

Compatibility

Designed for the ICP/Tempstar/Heil RGS121SFCA0AAA and other units using a 2-pole 30A 24V-coil contactor. Verify amp rating, pole count, and coil voltage against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter across the line terminals.
  2. Access — Remove the unit's electrical access/service panel.
  3. Document — Photograph every wire and terminal position before disconnecting anything.
  4. Remove — Transfer wires one at a time (or photo first), then unscrew the old contactor from its mounting feet.
  5. Install — Mount the new contactor, reconnect line, load, and 24V coil leads exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor/fan energize.

Signs You Need a Replacement

  • System won't start or hums but won't engage
  • Loud buzzing or chattering from the contactor
  • Burned, pitted, or welded contacts
  • Compressor runs continuously even with no cooling call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121SFCA0AAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121SFCA0AAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121SFCA0AAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online