Overview

This genuine OEM 2-pole, 30-amp definite-purpose contactor (part 1178074) is the high-voltage switch for the ICP / Tempstar / Heil RGS121SFAA0AAAA. Its 24-volt coil is energized by the thermostat or control board on a call for cooling, pulling the contacts closed to feed line voltage to the compressor and condenser fan motor. Because the contacts carry full load current and arc every cycle, they are one of the most common wear items in any HVAC system. Pitted, welded, or chattering contacts cause hard starts, no-cool conditions, or a unit that runs even with the thermostat satisfied. This 30A 2-pole replacement restores clean, reliable switching.

Specifications

Spec Value
Part Number 1178074
Type Definite-purpose contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24 VAC

Compatibility

Direct-fit replacement for the ICP RGS121SFAA0AAAA and a wide range of ICP-family condensing units (Tempstar, Heil, Comfortmaker) calling for a 2-pole 30A 24V definite-purpose contactor. Verify pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter at the contactor line terminals.
  2. Access — Remove the unit's electrical service panel.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Label and disconnect all leads, then unscrew the old contactor from the mounting plate.
  5. Install — Mount the new 2-pole 30A contactor and reconnect line, load, and coil wires exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and the compressor and fan energize.

Signs You Need a Replacement

  • Buzzing, chattering, or humming from the contactor
  • Pitted, blackened, or welded-together contacts
  • Compressor won't start or runs even when thermostat is off
  • 24V coil tests open or fails to pull the contacts in

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121SFAA0AAAA — Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121SFAA0AAAA — Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121SFAA0AAAA — Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online