Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS121LRCA0AAA — OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS121LRCA0AAA — OEM 1178074 | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM definite-purpose contactor (part number 1178074) is a 2-pole, 30-amp unit with a 24-volt control coil for the ICP / Tempstar / Heil RGS121LRCA0AAA system. The contactor is an electrically operated switch: when the 24V thermostat circuit energizes the coil, the contacts close and pass line voltage to the compressor and/or condenser fan motor. Contactors fail from arcing, pitted or welded contacts, and burned-out coils — common after years of high-cycle operation. A worn contactor causes hard starts, chattering, or a system that won't run at all.

Specifications

Spec Value
Part Number 1178074
Type Definite-Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24 VAC
Fit OEM

Compatibility

Built for the ICP RGS121LRCA0AAA and other RGS121-platform units sold under the ICP, Tempstar, and Heil brands. Verify the existing contactor is rated 2-pole, 30A, with a 24V coil before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and pull the outdoor disconnect. Verify zero voltage with a multimeter across the contactor terminals.
  2. Access — Remove the unit's electrical service panel.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Move wires one at a time from the old contactor to the new one, or label them; unscrew and remove the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power, call for cooling/heating, and confirm the contacts pull in cleanly with no chatter.

Signs You Need a Replacement

  • Buzzing, humming, or chattering at the contactor
  • Pitted, blackened, or welded-shut contacts
  • System won't start or runs intermittently
  • Coil fails to pull the contacts in on a thermostat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121LRCA0AAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121LRCA0AAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121LRCA0AAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online