Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS121LDAA0AAAA — OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS121LDAA0AAAA — OEM 1178074 | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp contactor with a 24-volt coil (factory part 1178074) is the switching relay for the ICP/Tempstar/Heil RGS121LDAA0AAAA system. When the thermostat calls, the 24V control signal energizes the coil, pulling the contacts closed to send line voltage to the compressor and condenser fan motor. Contactors are a high-wear item: the contacts arc every cycle and eventually pit, burn, or weld. Symptoms of failure include a system that won't start, a humming or chattering contactor, or a unit that runs continuously because the contacts welded shut. Replacing a worn contactor restores reliable, safe switching and protects the compressor from low-voltage and chatter damage.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24 VAC
Brand ICP (Tempstar / Heil)
Fits Model RGS121LDAA0AAAA

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil/Comfortmaker RGS121LDAA0AAAA and other units calling for a 2-pole 30A 24V definite-purpose contactor. Verify pole count, amp rating, and coil voltage against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical access/service panel.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Transfer wires one at a time (or label them), then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor, reconnect line, load, and 24V coil wires exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call and the compressor and fan energize normally.

Signs You Need a Replacement

  • System won't start or starts intermittently.
  • Loud humming, buzzing, or chattering from the contactor.
  • Pitted, burned, or welded contacts.
  • Unit runs nonstop because contacts won't release.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121LDAA0AAAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121LDAA0AAAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121LDAA0AAAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online