Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS120LSBB0AAA | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS120LSBB0AAA | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 2-pole, 30-amp contactor with a 24V coil, part number 1178074, is the switching workhorse for ICP/Tempstar/Heil systems such as the RGS120LSBB0AAA. When the thermostat calls, the 24V coil pulls in the contacts to deliver line voltage to the compressor and condenser fan motor. Contactors are high-wear items: the contacts arc on every cycle and eventually pit, weld, or fail to close. Symptoms of a failing contactor include a system that won't start, a chattering or buzzing relay, a unit that won't shut off (welded contacts), or burnt/pitted contact faces. Replacing a worn 30A contactor restores clean, reliable switching and protects the compressor from low-voltage damage.

Specifications

Spec Value
Part Number 1178074
Type Contactor, 2-pole
Brand ICP / Tempstar / Heil
Contact Rating 30A
Coil Voltage 24V
Poles 2

Compatibility

Fits the ICP/Tempstar/Heil RGS120LSBB0AAA and other ICP-family units specifying part 1178074. Verify pole count, amp rating, and 24V coil match your existing contactor.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them; unfasten the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and the compressor/fan energize.

Signs You Need a Replacement

  • System won't start despite a valid call for cooling
  • Loud chattering or buzzing from the contactor
  • Unit won't shut off (welded contacts)
  • Pitted, burnt, or discolored contact faces

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120LSBB0AAA | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120LSBB0AAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120LSBB0AAA | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online