Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS120LRCB0AAA — Definite Purpose | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS120LRCB0AAA — Definite Purpose | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 2-pole definite-purpose contactor (part 1178074) for the ICP / Tempstar / Heil RGS120LRCB0AAA. Rated at 30 amps per pole with a 24-volt control coil, this contactor uses the low-voltage thermostat/control signal to switch line-voltage power to the contactor's load. When the 24V coil is energized, the contacts pull in and pass power; when de-energized, a spring opens the contacts. Failure symptoms include pitted or welded contacts that won't release, a chattering or humming coil, and the system failing to start or failing to shut off. Replacing a worn contactor restores reliable switching and protects downstream components from arcing and voltage drop.

Specifications

Spec Value
OEM Part Number 1178074
Type Definite-purpose contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fitment OEM direct replacement

Compatibility

Built for the ICP-family RGS120LRCB0AAA and other ICP, Tempstar, Heil, and Comfortmaker systems specifying a 2-pole 30A contactor with a 24V coil (OEM 1178074). Confirm pole count, amp rating, and coil voltage against your existing unit before ordering.

Installation Guide

  1. Safety First — Disconnect line and control power; verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the electrical/service panel to reach the contactor.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unmount the old contactor.
  5. Install — Mount the new 2-pole contactor and reconnect each wire per your photo, matching line, load, and coil terminals.
  6. Test — Restore power and confirm the contacts pull in on a call and drop out cleanly when satisfied.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts that won't open or close
  • Loud humming or chattering from the coil
  • System fails to start, or fails to shut off when it should
  • Visible arcing, melting, or corrosion on the terminals

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120LRCB0AAA — Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120LRCB0AAA — Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120LRCB0AAA — Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online