Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS120LECB0AAA — OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS120LECB0AAA — OEM 1178074 | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 2-pole, 30-amp contactor with a 24V coil (part 1178074) for the ICP/Tempstar/Heil RGS120LECB0AAA system. The contactor is an electrically operated switch that closes its two power poles when the 24V control circuit energizes the coil, sending line voltage to the compressor and condenser fan motor. Worn, pitted, or burned contacts cause hard starting, chattering, or a unit that won't run at all; a failed coil leaves the contactor unable to pull in even with a valid 24V call.

Specifications

Spec Value
Part Number 1178074
Type Contactor, 2-Pole
Rating 30A
Coil Voltage 24V
Poles 2
Brand ICP / Tempstar / Heil
Fitment OEM Replacement

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil RGS120LECB0AAA system. This 2-pole 30A 24V contactor is a common spec across many ICP-family condensing units — confirm pole count (2), amp rating (30A), and 24V coil against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical access panel.
  3. Document — Photograph every line, load, and coil wire on the existing contactor before disconnecting.
  4. Remove — Label and remove each wire, unfasten the contactor's mounting screws, and lift it out.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and start a cooling call; confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Buzzing or chattering when the unit calls to run
  • Compressor/fan won't start despite a 24V signal
  • Visible arcing or melted contactor housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120LECB0AAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120LECB0AAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120LECB0AAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online