This OEM 2-pole, 30-amp contactor with a 24V coil (part 1178074) is the switching relay for the ICP / Heil / Tempstar RGS120LEAB0AAA system. When the thermostat or control board sends 24 volts to the coil, the contactor's two poles close and pass line voltage to the connected load. A failed contactor is one of the most common no-cool/no-run service calls: pitted or welded contacts, a burned-out coil, or chattering will prevent the system from energizing or cause it to run intermittently. Installing the correct 30A 24V OEM contactor restores clean, reliable switching and protects downstream components.

Specifications

Spec Value
Part Number 1178074
Type Definite purpose contactor
Brand ICP / Heil / Tempstar
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Fit OEM Replacement

Compatibility

Built for the ICP / Heil / Tempstar RGS120LEAB0AAA and other units that use a 2-pole 30A contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the contactor.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Disconnect the leads, unscrew the old contactor, and lift it out.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for operation, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • System will not start on a call for operation
  • Buzzing or chattering from the contactor
  • Pitted, burned, or welded contacts
  • Intermittent running or contacts that stick closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120LEAB0AAA — OEM Definite Purpose Contactor | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120LEAB0AAA — OEM Definite Purpose Contactor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120LEAB0AAA — OEM Definite Purpose Contactor | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online