Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS120HSAA0AGAA | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS120HSAA0AGAA | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM definite-purpose contactor, part number 1178074, for the ICP / Heil / Tempstar RGS120HSAA0AGAA furnace. It is a 2-pole, 30-amp contactor with a 24-volt control coil. When the thermostat or control board energizes the 24V coil, the electromagnet pulls the contacts closed and passes line voltage to the connected load. Contactors are high-cycle components: the contacts arc every time they open and close, so over thousands of cycles they pit, burn, and eventually weld shut or fail to make contact – a leading cause of no-start and chattering complaints.

Specifications

Spec Value
Part Number 1178074
Type Definite-purpose contactor, 2-pole
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Brand ICP (Heil / Tempstar)
Fit OEM
Compatible Model RGS120HSAA0AGAA

Compatibility

Designed for the ICP RGS120HSAA0AGAA furnace and broadly compatible with ICP-built Heil, Tempstar, and Comfortmaker equipment specifying a 2-pole 30A 24V coil contactor. Match pole count, amp rating, and coil voltage before installing.

Installation Guide

  1. Safety First – Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access – Remove the electrical/control service panel.
  3. Document – Photograph every wire and terminal position before disconnecting.
  4. Remove – Transfer wires one at a time, then unscrew and lift out the old contactor.
  5. Install – Mount the new contactor and reconnect line, load, and 24V coil wires per your photo.
  6. Test – Restore power and confirm the contactor pulls in cleanly with no chatter on a call for operation.

Signs You Need a Replacement

  • Burned, pitted, or welded contacts.
  • Loud humming or chattering when energized.
  • System fails to start or runs intermittently.
  • Visible arcing, melted housing, or a buzzing coil.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120HSAA0AGAA | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120HSAA0AGAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120HSAA0AGAA | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online