This genuine OEM 2-pole, 30-amp contactor with a 24-volt coil (part number 1178074) is the primary switching relay for the ICP / Tempstar / Heil RGS120HFBB0AAA system. When the thermostat calls for cooling, the 24V control signal energizes the contactor coil, pulling the contacts closed to deliver line voltage to the compressor and condenser fan motor. Contactors are high-wear components: their contacts arc every time they open and close, eventually pitting, burning, or welding shut. A failing contactor causes hard starts, chattering, intermittent cooling, or a unit that won't shut off. Replacing it with the correct 30A 2-pole part restores clean, reliable switching.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor, 2-Pole
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Fitment Direct OEM replacement

Compatibility

Built for the ICP RGS120HFBB0AAA and equivalent Tempstar, Heil, and Comfortmaker units using a 2-pole 30A 24V coil contactor. Verify the original part's amp rating, pole count, and coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker. Verify zero voltage with a multimeter at the contactor terminals.
  2. Access — Remove the unit's electrical service panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Label and remove the wires, then unscrew the old contactor from its mounting.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photos.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor/fan energize.

Signs You Need a Replacement

  • Loud chattering or buzzing from the contactor.
  • Pitted, burned, or welded contacts.
  • Compressor won't start or won't shut off.
  • Intermittent cooling or hard-starting condenser.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120HFBB0AAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120HFBB0AAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120HFBB0AAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.