This genuine ICP 2-pole, 30-amp definite purpose contactor (OEM part 1178074) features a 24-volt control coil and switches line voltage to the compressor and condenser fan in ICP / Tempstar / Heil equipment associated with the RGS120HFBA0AAA system. When the thermostat calls for cooling, the 24V coil energizes and pulls the contacts closed, sending power to the load. Over time the silver contacts pit, burn, or weld from arcing, and the coil can fail open — resulting in a system that won't start, chatters, hums, or runs continuously. Replacing a worn contactor restores clean, reliable switching and protects downstream components from voltage drop and overheating.

Specifications

Spec Value
Part Number 1178074
Type Definite purpose contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP (Tempstar / Heil)
Fitment OEM

Compatibility

Fits the ICP / Tempstar / Heil RGS120HFBA0AAA system and other ICP-family condensing units calling for a 2-pole 30A contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical access panel.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Transfer wires one at a time to the new contactor, or unfasten and lift out the old contactor after labeling leads.
  5. Install — Mount the new contactor, land each wire per your photo, and confirm the coil terminals (24V) are correctly connected.
  6. Test — Restore power, initiate a cooling call, and verify the contacts pull in and the compressor/fan energize.

Signs You Need a Replacement

  • System won't start or only starts intermittently
  • Buzzing, humming, or chattering from the contactor
  • Pitted, burned, or welded contacts
  • Compressor/fan run continuously after the call ends

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120HFBA0AAA — OEM Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120HFBA0AAA — OEM Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120HFBA0AAA — OEM Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online