This OEM 2-pole, 30-amp contactor with a 24V coil — part number 1178074 — switches line-voltage power to motor and compressor loads in your ICP/Heil/Tempstar RGS120HEAB0AGAA system. When the 24V control circuit energizes the coil, the contactor pulls in and closes both poles to deliver power; when the call ends, it drops out. Contactors are high-wear parts: their contacts pit, burn, and weld over thousands of cycles. A failed contactor shows up as a system that won't start, contacts that buzz/chatter, or contacts welded closed so the equipment runs nonstop. This direct OEM replacement restores clean, reliable switching.
| Spec | Value |
|---|---|
| Part Number | 1178074 |
| Type | Definite Purpose Contactor |
| Poles | 2-Pole |
| Contact Rating | 30 Amps |
| Coil Voltage | 24V |
| Brand | ICP (Heil / Tempstar / Comfortmaker) |
| Fitment | OEM Direct Replacement |
Direct OEM replacement for the 2-pole 30A 24V contactor used in the ICP/Heil/Tempstar/Comfortmaker RGS120HEAB0AGAA. Confirm pole count, the 30A contact rating, and 24V coil voltage match your existing contactor before installing.