Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS102LSAB0AAA — OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS102LSAB0AAA — OEM 1178074 | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp contactor with a 24-volt coil (part number 1178074) is the switching relay for the ICP / Tempstar / Heil RGS102LSAB0AAA system. When the thermostat calls for cooling or compressor operation, the 24V control signal energizes the coil, pulling the contacts closed to deliver line voltage to the compressor and condenser fan motor. Because the contacts carry high current and cycle thousands of times per season, they are one of the most common wear items in HVAC equipment. Failure symptoms include pitted or welded contacts, a loud buzzing or chattering from the coil, the compressor failing to start, or the unit running continuously because the contacts have welded shut. Replacing a worn contactor restores reliable starting and protects the compressor from low-voltage and chatter damage.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Fit OEM Replacement

Compatibility

Designed for the ICP Tempstar Heil RGS102LSAB0AAA and compatible RGS-series equipment using a 2-pole 30A 24V contactor. Verify your existing contactor's pole count, amp rating, and 24V coil against part 1178074 before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker. Verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the control panel cover to expose the contactor.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and disconnect each wire, then unfasten the old contactor from its mounting.
  5. Install — Mount the new contactor and transfer each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contacts pull in on a cooling call and the compressor and fan start normally.

Signs You Need a Replacement

  • Buzzing, humming, or chattering from the contactor
  • Pitted, burned, or welded contacts
  • Compressor or condenser fan won't start
  • Unit runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102LSAB0AAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102LSAB0AAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102LSAB0AAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online