Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS102HTCA0AAA — 30 Amp Contactor | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS102HTCA0AAA — 30 Amp Contactor | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole, 30-amp contactor with a 24-volt coil (part number 1178074) for the ICP / Tempstar / Heil RGS102HTCA0AAA. The contactor is the electrically-operated switch that energizes the compressor and condenser fan motor. When the thermostat calls for cooling, 24 volts energizes the coil, pulling the contacts closed to send line voltage to the high-voltage loads. Over time the contacts pit, burn, and weld from repeated arcing, which is one of the most common no-cool service calls. Symptoms include a system that won't start, contacts that buzz or chatter, a unit that won't shut off because the contacts have welded closed, or visible burning and pitting on the contact points.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Pole Configuration 2-Pole (Double Pole)
Contact Rating 30 Amps
Coil Voltage 24 VAC
Fit OEM Replacement

Compatibility

Fits the ICP/Tempstar/Heil RGS102HTCA0AAA and other ICP-family units specifying a 2-pole 30A definite-purpose contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical access panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, then unfasten the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the coil pulls in and the compressor/fan energize on a cooling call.

Signs You Need a Replacement

  • Compressor and condenser fan won't start on a call for cooling
  • Buzzing, humming, or chattering at the contactor
  • System won't shut off (contacts welded closed)
  • Pitted, burned, or melted contact points

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102HTCA0AAA — 30 Amp Contactor | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102HTCA0AAA — 30 Amp Contactor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102HTCA0AAA — 30 Amp Contactor | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online