This OEM 2-pole, 30-amp contactor (part #1178074) with a 24V coil is the switching relay for the ICP / Tempstar / Heil RGS101SEAB0AAAA. When the thermostat calls, the 24-volt coil pulls the contacts closed and sends line power to the load. Contactors are a high-wear part: the contacts pit and burn over thousands of cycles. A failing contactor shows up as a system that won't start, chatters, buzzes loudly, or runs continuously because the contacts have welded shut.

Specifications

Spec Value
Part Number 1178074
Type Definite-purpose contactor
Poles 2-pole
Contact Rating 30 Amp
Coil Voltage 24V
Brand ICP (Tempstar / Heil)

Compatibility

Direct OEM fit for the ICP RGS101SEAB0AAAA and its Tempstar, Heil, Comfortmaker, and Arcoaire equivalents. Verify the 2-pole/30A/24V rating matches your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect switch. Verify zero voltage with a multimeter.
  2. Access — Remove the service panel to expose the control compartment.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Move wires one at a time to the new contactor, or label them; unscrew the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a thermostat call with no chatter.

Signs You Need a Replacement

  • Loud buzzing or chattering when the unit tries to start
  • Burned, pitted, or welded contacts
  • System won't energize on a call for cooling/heat
  • Unit runs nonstop because contacts stuck closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS101SEAB0AAAA — OEM Part 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS101SEAB0AAAA — OEM Part 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS101SEAB0AAAA — OEM Part 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.