This genuine OEM 2-pole, 30 amp contactor with a 24-volt coil (part #1178074) fits the ICP / Heil / Tempstar RGS101LRCB0AAA system. The contactor is an electromagnetic switch: when the 24V control circuit energizes the coil, the contacts close and pass line voltage to the compressor and condenser fan motor. Contactors are high-wear parts — their contacts pit, burn, and weld over thousands of cycles. A failing 30A contactor causes hard starting, chattering, a unit that won't start, or a compressor that won't shut off because the contacts have welded closed. Replacing it with the correct 2-pole 30A 24V OEM part restores reliable switching.

Specifications

Spec Value
Part Number 1178074
Type 2-Pole Contactor
Brand ICP / Heil / Tempstar
Contact Rating 30 Amp
Coil Voltage 24 VAC
Poles 2
Fitment OEM

Compatibility

Fits the ICP RGS101LRCB0AAA and related Heil, Tempstar, and Comfortmaker units using a 2-pole 30A 24V contactor. Match poles, amp rating, and coil voltage to your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control panel cover.
  3. Document — Photograph every wire on the contactor before disconnecting.
  4. Remove — Transfer wires one at a time or label them, remove mounting screws, and lift out the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor/fan start cleanly.

Signs You Need a Replacement

  • Buzzing or chattering at the contactor
  • Compressor won't start or starts hard
  • Pitted, burned, or welded contacts
  • Unit won't shut off on a satisfied thermostat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS101LRCB0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS101LRCB0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS101LRCB0AAA — OEM Replacement | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online