Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS091SRBB0AAAA — 30 Amp | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS091SRBB0AAAA — 30 Amp | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 2-pole, 30-amp definite-purpose contactor (part 1178074) switches line power to the compressor and condenser fan in the ICP Tempstar Heil RGS091SRBB0AAAA system. A 24-volt control signal from the thermostat energizes the coil, pulling the contacts closed to start the outdoor unit. Over time the silver contacts pit, burn, or weld from arcing, and the coil can fail — causing the unit to fail to start, chatter, or run continuously. Replacing a worn contactor restores reliable starting and prevents damage to the compressor.

Specifications

Spec Value
Part Number 1178074
Type Definite-purpose contactor, 2-pole
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2
Fitment OEM

Compatibility

Fits the ICP Tempstar Heil RGS091SRBB0AAAA and other ICP-family condensing units that use a 2-pole, 30A, 24V contactor. Verify amperage, pole count, and coil voltage against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing-unit electrical panel.
  3. Document — Photo all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer one wire at a time, or label leads, then unscrew and remove the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the unit starts cleanly.

Signs You Need a Replacement

  • Outdoor unit won't start or hums without engaging
  • Buzzing, chattering, or rapid clicking at the contactor
  • Pitted, burned, or welded contacts
  • Compressor runs even after the thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091SRBB0AAAA — 30 Amp | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091SRBB0AAAA — 30 Amp | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091SRBB0AAAA — 30 Amp | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online