Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS091SRAB0AAAA — OEM Fit | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS091SRAB0AAAA — OEM Fit | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 2-pole 30-amp contactor (part 1178074) with a 24-volt coil is the primary switching device for the ICP / Tempstar / Heil RGS091SRAB0AAAA. When the thermostat calls and the 24V control circuit energizes the coil, the contactor's two poles close to deliver line power to the load. Contactors are high-cycle components — the contact points pit, burn, and weld over time, while the coil can fail open. Symptoms of a worn contactor include chattering, a buzzing hum, contacts that stick closed (system won't shut off), or contacts that won't pull in (system won't start). This 30A 2-pole contactor restores reliable, positive switching.

Specifications

Spec Value
Part Number 1178074
Type Contactor, 2-Pole
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2
Fit OEM Direct Replacement

Compatibility

Direct-fit for the ICP-built RGS091SRAB0AAAA and the shared Tempstar / Heil / Comfortmaker platforms using a 2-pole 30A 24V coil contactor. Verify amp rating, pole count, and coil voltage against your existing unit.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the electrical control panel cover.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unfasten and remove the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a call with no chatter.

Signs You Need a Replacement

  • Buzzing, humming, or chattering at the contactor
  • Pitted, burned, or welded contact points
  • System won't start (coil not pulling in)
  • System won't shut off (contacts stuck closed)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091SRAB0AAAA — OEM Fit | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091SRAB0AAAA — OEM Fit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091SRAB0AAAA — OEM Fit | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online