Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS091LRBB0AAAA — OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS091LRBB0AAAA — OEM 1178074 | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM 2-pole, 30-amp contactor with a 24-volt coil (part number 1178074) for the ICP / Heil / Tempstar RGS091LRBB0AAAA unit. A contactor is an electrically controlled switch: when the 24V control circuit energizes the coil, the contactor pulls in and passes line voltage to the load. Over time the contact points pit, burn, and weld from the constant arcing of switching high current, which causes the unit to chatter, fail to start, or fail to shut off. This direct-fit OEM contactor restores clean, reliable switching with 30A-rated 2-pole contacts and a standard 24VAC coil.

Specifications

Spec Value
Part Number 1178074 (CONTACTOR 2P 30A 24V)
Type Definite-purpose contactor
Poles 2-pole
Contact Rating 30 Amps
Coil Voltage 24 VAC
Brand ICP / Heil / Tempstar

Compatibility

Fits the ICP/Heil/Tempstar RGS091LRBB0AAAA and other units originally equipped with a 2-pole 30A 24V contactor matching part 1178074. Confirm pole count, contact amperage, and coil voltage match your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter on all terminals.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photograph every wire on the line, load, and coil terminals before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unscrew and remove the old contactor.
  5. Install — Mount the new 1178074 contactor and reconnect each wire to the matching terminal per your photos.
  6. Test — Restore power, initiate a call for operation, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Loud humming, buzzing, or chattering from the contactor
  • Unit will not start even though the coil is energized
  • Pitted, burned, or welded (stuck-closed) contacts
  • Unit fails to shut off because the contacts are fused together

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091LRBB0AAAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091LRBB0AAAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091LRBB0AAAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online