This OEM 2-pole, 30-amp definite purpose contactor (P/N 1178074) with a 24-volt coil is the switching relay that powers the compressor and condenser fan in the ICP RGS091LRBA0AAAA system. When the thermostat calls for cooling, the 24V control signal energizes the coil, pulling the contacts closed to deliver line voltage to the high-current loads. Contactors are among the most common HVAC failure points: the contacts pit and burn from repeated arcing, and the coil can fail open, leaving the system unable to start. Symptoms include a humming or chattering contactor, contacts that weld closed (system runs continuously), or no compressor operation at all. Replacing a worn contactor restores clean, reliable switching and protects downstream components.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2
Rating 30 Amps
Coil Voltage 24V
Fitment OEM
Model RGS091LRBA0AAAA

Compatibility

Fits the ICP / Tempstar / Heil RGS091LRBA0AAAA and other units calling for a 2-pole 30A definite purpose contactor with a 24V coil. Confirm amp rating and coil voltage against the part you are replacing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter across all terminals.
  2. Access — Remove the service panel to expose the contactor in the control box.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unfasten the old contactor from its mounting.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photos.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Loud humming or chattering when energized
  • Compressor and fan won't start despite a cooling call
  • System runs continuously because contacts stick closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091LRBA0AAAA — Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091LRBA0AAAA — Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091LRBA0AAAA — Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.