Overview

This genuine OEM 2-pole, 30-amp contactor (part 1178074) with a 24-volt coil switches line voltage to the compressor and condenser fan in the ICP Tempstar Heil RGS090SFAB0AGAA system. When the thermostat calls for cooling, the 24V control signal energizes the coil, pulling the contacts closed to power the outdoor unit. Contactors are high-wear parts — pitted, burned, or welded contacts and chattering coils are among the most common causes of a no-cool condition. Replacing a failing contactor restores reliable compressor and fan operation.

Specifications

Spec Value
Part Number 1178074
Type 2-Pole Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Fits Model RGS090SFAB0AGAA

Compatibility

Fits the ICP Tempstar Heil RGS090SFAB0AGAA and other ICP-family condensing units using a 2-pole 30A 24V contactor. Verify pole count, amp rating, and coil voltage against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the condenser unit electrical access panel.
  3. Document — Photograph all wire connections before disconnecting.
  4. Remove — Label and remove the wires, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and transfer wires one at a time per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor/fan start.

Signs You Need a Replacement

  • Burned, pitted, or welded contacts
  • Loud humming, buzzing, or chattering coil
  • Compressor and condenser fan won't start on a cooling call
  • Visible arcing or melted housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS090SFAB0AGAA — OEM Relay | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS090SFAB0AGAA — OEM Relay | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS090SFAB0AGAA — OEM Relay | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online