Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS090SFAA0AGAA — OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS090SFAA0AGAA — OEM 1178074 | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 2-pole, 30-amp contactor with a 24-volt coil (part number 1178074) for the ICP / Tempstar / Heil RGS090SFAA0AGAA system. The contactor is the heavy-duty switch that powers the compressor and condenser fan: when the thermostat sends 24V to the coil, the electromagnet pulls the contacts closed and sends line voltage to the load. It's one of the hardest-working parts in the system, cycling thousands of times per season.

Contactors wear out from arcing and heat. Pitted or welded contacts cause the compressor to run continuously even with no cooling call, while a failed coil or carbon-tracked contacts cause hard starts, chatter, or a complete no-start. Replacing a worn contactor restores clean, reliable switching and protects the compressor from voltage problems.

Specifications

Spec Value
Part Number 1178074
Type Definite-Purpose Contactor, 2-Pole
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24V AC
Poles 2
Fitment OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP RGS090SFAA0AGAA and related Tempstar, Heil, and Comfortmaker units using a 2-pole 30A 24V coil contactor (part 1178074). Match poles, amp rating, and coil voltage to your original before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control-box / service panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unscrew the old contactor from the panel.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor/fan energize.

Signs You Need a Replacement

  • Compressor runs nonstop or won't shut off
  • Loud humming, buzzing, or chattering at the contactor
  • Burned, pitted, or welded contacts
  • System won't start on a cooling call

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS090SFAA0AGAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS090SFAA0AGAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS090SFAA0AGAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online