Overview

This is the OEM 2-pole, 30 amp definite-purpose contactor with a 24V coil (OEM part 1178074) for the ICP / Heil / Tempstar RGS090SEAB0AAA system. The contactor is the electrically operated switch that energizes the compressor and condenser fan whenever the thermostat calls for cooling. Its 24-volt coil pulls the contacts closed to pass line voltage to the high-current loads. Because the contacts arc each time they open and close, they pit, burn, and weld over years of cycling — a leading cause of a unit that hums but won't start, or one that won't shut off. A genuine OEM contactor restores reliable, safe switching with the correct 30A rating and 24V coil.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Fit OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP/Heil/Tempstar RGS090SEAB0AAA and related models using a 2-pole 30A contactor with a 24V coil. Verify pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, verify zero voltage with a multimeter.
  2. Access — Remove the electrical/service panel.
  3. Document — Photograph all line, load, and coil wire connections before disconnecting.
  4. Remove — Label and transfer wires, then unscrew and remove the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor/fan start on a cooling call.

Signs You Need a Replacement

  • Unit hums or buzzes but compressor/fan won't start
  • Burnt, pitted, or welded contacts
  • System won't shut off when the call ends
  • Chattering contactor or melted/discolored housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS090SEAB0AAA — Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS090SEAB0AAA — Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS090SEAB0AAA — Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online