This OEM 2-pole, 30-amp contactor with a 24-volt coil (ICP part number 1178074) is the switching relay that energizes the high-voltage load circuit on the ICP/Heil/Tempstar RGS090LTAB0AAA. When the control board calls, the 24V coil pulls the contacts closed and sends line voltage to the load. Contactors are a common failure point because their contacts arc and pit over thousands of cycles. Symptoms of failure include a unit that won't start, chattering or buzzing at the contactor, welded contacts that won't drop out, or pitted/burned contact faces. Installing the exact OEM contactor restores clean, reliable switching.

Specifications

Spec Value
Part Number 1178074
Type Contactor, 2-Pole
Brand ICP / Heil / Tempstar
Contact Rating 30A
Coil Voltage 24V
Poles 2
Fit OEM exact replacement

Compatibility

Designed for the ICP/Heil/Tempstar/Comfortmaker RGS090LTAB0AAA and related units calling out the 1178074 contactor. Verify amp rating, pole count, and 24V coil against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and remove wires one at a time, then unfasten the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call and drops out cleanly.

Signs You Need a Replacement

  • Unit fails to start or starts intermittently
  • Loud buzzing, humming, or chattering at the contactor
  • Pitted, burned, or welded contacts
  • Coil that no longer pulls the contacts closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS090LTAB0AAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS090LTAB0AAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS090LTAB0AAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online