Overview

This genuine OEM 2-pole definite-purpose contactor energizes the compressor and condenser fan circuits in the ICP / Tempstar / Heil RGS150HEBA0AGAA. The contactor is controlled by a 24V coil: when the thermostat calls for cooling, the low-voltage coil pulls the contacts closed and passes line voltage to the load. Two amperage ratings fit this model — 30A (P/N 1178074) and 40A (P/N 1178211); select the rating that matches your existing contactor or the unit's wiring diagram. Contacts pit, weld, and burn over thousands of cycles, which is one of the most common causes of a no-cool call.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type 2-pole definite purpose
Poles 2
Coil Voltage 24V
Amp Rating 30A or 40A (per part)
Brand ICP (Tempstar / Heil)

Compatibility

Fits the RGS150HEBA0AGAA and related ICP-family equipment using a 2-pole 24V contactor. Match the amp rating (30A vs 40A) to your unit before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter on both line terminals.
  2. Access — Remove the service/electrical panel.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo, confirming coil leads land on the coil terminals.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter or arcing.

Signs You Need a Replacement

  • Compressor/condenser won't start on a cooling call
  • Buzzing, chattering, or humming at the contactor
  • Pitted, blackened, or welded contacts
  • Visible arcing or a burnt-plastic smell at the electrical panel

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150HEBA0AGAA — 30A / 40A | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150HEBA0AGAA — 30A / 40A | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150HEBA0AGAA — 30A / 40A | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online