This genuine OEM single-pole definite purpose contactor (part number 1050699) is the main switching relay for ICP, Tempstar, and Heil YJ024G outdoor units. Rated for 25 amps with a 24V control coil, the contactor pulls in when the thermostat calls for cooling, closing its contacts to send line voltage to the compressor and condenser fan motor. Over thousands of cycles the contact points pit, arc, and eventually weld or fail to close — a leading cause of outdoor units that won't start. Common symptoms include a condenser that hums but won't run, chattering or buzzing at the contactor, pitted or burnt contacts, and an outdoor unit that keeps running after the thermostat is satisfied (welded contacts). Replacing a worn contactor is inexpensive insurance against compressor damage.

Specifications

Spec Value
Part Number 1050699
Type Single-Pole (1-Pole) Contactor
Brand ICP / Tempstar / Heil
Contact Rating 25 Amps
Coil Voltage 24V AC
Poles 1
Fit OEM Replacement

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil YJ024G condensing unit and related single-phase platforms using a 25A, 24V single-pole contactor. Verify your existing contactor's amp rating, pole count, and coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit electrical access panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer wires one at a time, or label them; unscrew the mounting and lift out the old contactor.
  5. Install — Mount the new contactor and reconnect each wire per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor and fan start on a cool call.

Signs You Need a Replacement

  • Outdoor unit hums but won't start
  • Buzzing or chattering at the contactor
  • Pitted, burnt, or welded contact points
  • Compressor keeps running after the call ends

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YJ024G — 25A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YJ024G — 25A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YJ024G — 25A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online