Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole Contactor for YH030GC — 25A 24V Coil | Ships Today
ICP

ICP 1-Pole Contactor for YH030GC — 25A 24V Coil | Ships Today

SKU: YH030GC Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 1-pole, 25-amp contactor (part number 1050699) switches line power to the compressor and condenser fan on the ICP YH030GC heat pump. When the thermostat calls, the 24V coil pulls the contacts closed and energizes the outdoor unit; when the call ends, the contacts open. Over thousands of cycles the contacts pit, burn, and weld, or the coil weakens — leading to a unit that won't start, won't shut off, or chatters. Replacing a worn contactor is one of the most common and effective condenser repairs.

Specifications

Spec Value
Part Number 1050699
Description CONTACTOR 1P 25A 24V S
Type Definite Purpose Contactor
Poles 1
Contact Rating 25A
Coil Voltage 24V
Brand ICP / Heil / Tempstar

Compatibility

Fits the ICP/Heil/Tempstar/Comfortmaker YH030GC heat pump and equivalent condensing units that use a 1-pole, 25A definite-purpose contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage against your original before installing.

Installation Guide

  1. Safety First — Pull the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to reach the control box.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove — Move each wire one at a time, or label them, and unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and transfer each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit won't start, or contactor chatters and buzzes.
  • Pitted, burned, or welded contacts (unit won't shut off).
  • Coil won't pull the contacts closed on a 24V call.
  • Visible arcing, melted housing, or scorch marks.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YH030GC — 25A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YH030GC — 25A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YH030GC — 25A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online