Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole Contactor for YG036G — 25A 24V Coil | Ships Today
ICP

ICP 1-Pole Contactor for YG036G — 25A 24V Coil | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 1-pole, 25-amp contactor (part number 1050699) is the switching relay for the ICP/Heil/Tempstar YG036G. Its 24V control coil pulls in a single set of power contacts to energize the compressor and condenser fan motor each time the thermostat calls for cooling. Over thousands of cycles the contacts pit, burn, and weld — and the coil can fail open. Common failure symptoms include a unit that won't start, chattering or buzzing at the contactor, contacts that stick closed so the compressor never shuts off, and visible arcing or pitting on the contact faces. A new contactor is one of the most common and inexpensive HVAC repairs.

Specifications

Spec Value
Part Number 1050699
Type 1-Pole Contactor
Brand ICP / Heil / Tempstar
Contact Rating 25 Amps
Coil Voltage 24V
Poles 1

Compatibility

Direct OEM replacement for the ICP/Heil/Tempstar YG036G and other condensing units that use the 1050699 single-pole, 25A, 24V-coil contactor. Verify pole count, amp rating, and coil voltage against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit service panel to reach the control compartment.
  3. Document — Photograph all line, load, and 24V coil wiring before removing anything.
  4. Remove — Label and disconnect the wires, unscrew the contactor from its bracket, and lift it out.
  5. Install — Mount the new contactor, then reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor/fan start.

Signs You Need a Replacement

  • Loud chattering or buzzing when cooling is called
  • Compressor won't start or runs intermittently
  • Contacts welded shut so the unit never cycles off
  • Pitted, blackened, or burned contact faces

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YG036G — 25A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YG036G — 25A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YG036G — 25A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online