Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole Contactor for YG024GC2 — 25A 24V Coil | Ships Today
ICP

ICP 1-Pole Contactor for YG024GC2 — 25A 24V Coil | Ships Today

SKU: YG024GC2 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole definite purpose contactor (part number 1050699) is the high-voltage switch that powers the compressor and outdoor fan on your ICP / Tempstar / Heil YG024GC2 heat pump. Its 24V coil is energized by the thermostat through the control board; when energized, the 25-amp contacts close and feed line voltage to the condenser. Contactors are among the most common HVAC failures — the contacts pit, burn, and weld over thousands of cycles, while the coil can open or chatter. A failed contactor causes a no-start condition, a unit that hums but won't engage, or a compressor that won't shut off. Replacing it with the correct 25A, 24V-coil OEM part restores clean, reliable switching.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 1-Pole
Contact Rating 25A
Coil Voltage 24V
Application AC Compressor / Condenser Fan

Compatibility

Direct-fit OEM replacement for the ICP Tempstar Heil YG024GC2 heat pump and related YG024 series condensing units. Verify pole count, contact amperage, and 24V coil rating against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical service panel.
  3. Document — Photograph all line, load, and 24V coil wire connections before disconnecting.
  4. Remove — Transfer wires one at a time, or label and disconnect them, then unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call for cooling and the compressor/fan energize.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but the compressor and fan won't start.
  • Burnt, pitted, or welded contacts visible on the contactor.
  • Compressor won't shut off because the contacts have welded closed.
  • Chattering or no pull-in even with 24V present at the coil.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YG024GC2 — 25A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YG024GC2 — 25A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YG024GC2 — 25A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online