This OEM single-pole contactor (part number 1172472) is the main switching relay for the ICP WCH3422GKR3 heat pump/condensing unit. Rated at 30 amps with a 24-volt control coil and a built-in shunt, it energizes the compressor and outdoor fan motor whenever the thermostat calls for cooling. When the 24V coil is powered, the electromagnet closes the contacts and passes line voltage to the outdoor equipment. After thousands of cycles the contacts pit, burn, or weld, and the coil can open or short. A worn contactor is a leading cause of an outdoor unit that hums but won't start, chatters, or runs nonstop after the call ends. Installing a fresh contactor restores reliable switching and shields the costly compressor from low-voltage faults.

Specifications

Spec Value
Part Number 1172472
Type Definite Purpose Contactor, 1-Pole
Brand ICP (Tempstar / Heil)
Contact Rating 30 Amps
Coil Voltage 24V
Poles 1
Features Integrated shunt
Fit OEM Replacement

Compatibility

Engineered as a direct OEM fit for the ICP WCH3422GKR3 outdoor unit and the matching Tempstar, Heil, and Comfortmaker variants on the same chassis. Verify the existing contactor is a 1-pole, 30A, 24V coil unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.
  2. Access — Remove the electrical access panel on the condensing unit.
  3. Document — Photograph every wire and terminal position before disconnecting anything.
  4. Remove — Note line, load, and 24V coil leads, transfer one wire at a time, then unbolt the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but the compressor and fan won't start.
  • Visible pitting, burning, or melted plastic on the contacts.
  • Chattering or rapid clicking when the thermostat calls for cooling.
  • Unit runs continuously and won't shut off because the contacts have welded closed.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH3422GKR3 — 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH3422GKR3 — 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH3422GKR3 — 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online