Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole Contactor 30A for WPG3244060RKC1 — 24V Coil w/ Shunt | Ships Today
ICP

ICP 1-Pole Contactor 30A for WPG3244060RKC1 — 24V Coil w/ Shunt | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM single-pole definite purpose contactor (part number 1172472) replaces the switching contactor in the ICP Tempstar Heil WPG3244060RKC1. Rated for 30 amps with a 24-volt coil and an integrated shunt, it energizes the compressor and condenser fan circuit each time the thermostat calls for cooling. Contactors endure thousands of make-and-break cycles, so pitted or welded contacts are a leading cause of no-cool failures and chattering at the outdoor unit.

Specifications

Spec Value
Part Number 1172472
Type Definite Purpose Contactor, 1-Pole
Brand ICP (Tempstar / Heil)
Contact Rating 30 Amps
Coil Voltage 24V
Features Integrated shunt

Compatibility

A direct-fit replacement for the ICP / Tempstar / Heil WPG3244060RKC1 and other units specifying OEM part 1172472. Verify amperage, pole count, and the 24V coil rating against the failed contactor before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter at the contactor line terminals.
  2. Access — Remove the service panel to reach the electrical compartment.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each lead per your photo, confirming the 24V coil terminals are correct.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a cooling call with no chatter.

Signs You Need a Replacement

  • Buzzing or chattering at the outdoor unit
  • Pitted, burned, or welded contacts
  • Compressor and fan fail to energize on a cooling call
  • Contactor will not pull in or drops out intermittently

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG3244060RKC1 — 24V Coil w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG3244060RKC1 — 24V Coil w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG3244060RKC1 — 24V Coil w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online