Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole Contactor 30A 24V for WPG3304040RKC1 — With Shunt | Ships Today
ICP

ICP 1-Pole Contactor 30A 24V for WPG3304040RKC1 — With Shunt | Ships Today

SKU: 1172472-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM single-pole definite purpose contactor (part number 1172472) is the switching relay for the ICP / Tempstar / Heil WPG3304040RKC1. Rated 30 amps with a 24-volt control coil and an integrated shunt, it energizes the compressor and condenser fan whenever the thermostat calls for cooling. Contactors are one of the most common HVAC failure points: the contacts arc and pit with every cycle, eventually welding shut, chattering, or refusing to pull in. A failed contactor leaves the outdoor unit either dead or unable to shut off. Replacing it with the correct OEM part restores reliable switching and protects the compressor from chatter-induced damage.

Specifications

Spec Value
Part Number 1172472
Type Definite Purpose, 1-Pole, with Shunt
Brand ICP (Tempstar / Heil)
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 1
Fits Model WPG3304040RKC1

Compatibility

Built for the ICP WPG3304040RKC1 and interchangeable across many Tempstar, Heil, Comfortmaker, and Day & Night packaged units using a 1-pole 30A 24V contactor. Verify your existing coil voltage (24V) and amp rating before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the control area.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or label each, then unscrew and lift out the old contactor.
  5. Install — Mount the new contactor, land each wire on the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the unit energizes.

Signs You Need a Replacement

  • Outdoor unit will not start on a cooling call
  • Buzzing, humming, or chattering at the contactor
  • Contacts are pitted, blackened, or welded together
  • Unit fails to shut off when the thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG3304040RKC1 — With Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG3304040RKC1 — With Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG3304040RKC1 — With Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online