Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 40A Contactor for WTA3482000RKA1 — 24V Coil | Ships Today
ICP

ICP 1-Pole 40A Contactor for WTA3482000RKA1 — 24V Coil | Ships Today

SKU: 1173690 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole contactor (part number 1173690) is rated 40 amps with a 24-volt control coil and is the factory-specified switching relay for the ICP WTA3482000RKA1 condensing unit. The contactor is the heavy-duty electrical switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. When the 24V coil is energized it pulls the contacts closed, passing line voltage to the outdoor unit. With repeated arcing the silver contacts pit, burn, or weld, and the coil can eventually fail. Symptoms include an outdoor unit that will not start, a buzzing or chattering contactor, pitted or blackened contacts, and an AC that runs nonstop because the contacts have welded shut. A new contactor restores reliable, safe switching of the condenser.

Specifications

Spec Value
Part Number 1173690
Type Single-Pole (1P)
Brand ICP
Contact Rating 40 Amps
Coil Voltage 24V
Fits Model WTA3482000RKA1

Compatibility

Engineered for the ICP / Tempstar / Heil WTA3482000RKA1 air conditioning condenser. Confirm a 1-pole, 40A, 24V-coil contactor matches your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Label and transfer wires one at a time, unscrew the mounting screws, and remove the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and verify the contactor pulls in cleanly and the unit starts.

Signs You Need a Replacement

  • Outdoor unit will not start on a cooling call
  • Contactor buzzes, chatters, or hums
  • Pitted, burned, or welded contacts
  • AC runs nonstop and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WTA3482000RKA1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WTA3482000RKA1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WTA3482000RKA1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online