Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 40A Contactor for WPG4604115RKB1 — 24V Coil | Ships Today
ICP

ICP 1-Pole 40A Contactor for WPG4604115RKB1 — 24V Coil | Ships Today

SKU: 1173690 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole contactor (part number 1173690) is the switching relay that powers the compressor and condenser fan on the ICP/Tempstar/Heil WPG4604115RKB1. Rated at 40 amps with a 24V control coil, it energizes when the thermostat calls for cooling, closing its main contacts to feed line voltage to the compressor. Over time the contacts pit, burn, or weld from arcing, and the coil can fail open — leaving you with a unit that hums but won't start, chatters, or runs continuously. Installing a fresh 1-pole 40A contactor restores reliable, clean switching.

Specifications

Spec Value
Part Number 1173690
Type Definite Purpose Contactor, Single Pole
Brand ICP (Tempstar / Heil)
Contact Rating 40 Amps
Coil Voltage 24 VAC
Poles 1
Fitment OEM Direct Replacement

Compatibility

Direct fit for the ICP/Tempstar/Heil WPG4604115RKB1 packaged gas/electric unit and other ICP-family systems specifying a 1-pole, 40A, 24V definite-purpose contactor.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control-compartment service panel.
  3. Document — Photograph all line, load, and coil wires before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unbolt the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor and fan start.

Signs You Need a Replacement

  • Unit hums but compressor won't start
  • Contactor chatters or buzzes loudly
  • Burned, pitted, or welded contacts
  • Compressor runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG4604115RKB1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG4604115RKB1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG4604115RKB1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online