This OEM definite-purpose contactor (part 1173690) is the high-voltage switch that powers the compressor and condenser fan on your ICP/Heil/Tempstar WPG4604115RKA1. When the 24V control circuit energizes the coil, the contactor's electromagnet pulls the contacts closed and sends line voltage to the compressor; when the thermostat is satisfied, the coil de-energizes and the contacts open. Rated 40 amps with a single pole and a 24V coil, it is built for the inrush and continuous load of a residential package unit. Contactors are a leading cause of no-cool calls: pitted or welded contacts can stop the unit from starting, cause it to chatter, or weld closed so the compressor never shuts off. A burnt coil simply will not pull the contacts in even with 24V present.
| Spec | Value |
|---|---|
| Part Number | 1173690 |
| Type | Definite-purpose contactor |
| Brand | ICP / Heil / Tempstar |
| Poles | 1-pole |
| Rating | 40 Amp |
| Coil Voltage | 24V |
| Fit | OEM direct replacement |
Direct OEM fit for the ICP/Heil/Tempstar/Comfortmaker WPG4604115RKA1 and ICP-family package units specifying a 1-pole, 40A, 24V-coil contactor. Verify pole count, amp rating, and coil voltage against your existing part before installing.