Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 40A Contactor for WPG4484130LKA1 – 24V Coil | Ships Today
ICP

ICP 1-Pole 40A Contactor for WPG4484130LKA1 – 24V Coil | Ships Today

SKU: 1173690 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole contactor (part number 1173690) is the electrical switch that controls power to the condenser unit on your ICP WPG4484130LKA1 system. Rated for 40 amps with a 24-volt control coil, it energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. The contactor is one of the most frequently failed components in an outdoor unit because its contacts arc and pit with every cycle. Common failure symptoms include a unit that won't start, a humming or chattering sound at the contactor, welded contacts that keep the compressor running continuously, or visible burning and pitting on the contact points.

Specifications

Spec Value
Part Number 1173690
Type Definite Purpose Contactor
Brand ICP
Poles 1-Pole
Current Rating 40 Amps
Coil Voltage 24V

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil WPG4484130LKA1 condensing unit. This contactor is used across many ICP-family package units and condensers that share the same 40A, 24V control architecture.

Installation Guide

  1. Safety First – Disconnect power at the disconnect box and breaker, then verify zero voltage with a multimeter.
  2. Access – Remove the condenser service panel to expose the control area.
  3. Document – Photograph all wire connections before disconnecting anything.
  4. Remove – Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its bracket.
  5. Install – Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test – Restore power and confirm the contactor pulls in and the compressor and fan start on a cooling call.

Signs You Need a Replacement

  • Outdoor unit won't start or starts intermittently
  • Loud humming, buzzing, or chattering at the contactor
  • Pitted, burnt, or welded contact points
  • Compressor runs continuously even when thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG4484130LKA1 – 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG4484130LKA1 – 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG4484130LKA1 – 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online