Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 40A Contactor for WPG4484115RKB1 — 24V Coil | Ships Today
ICP

ICP 1-Pole 40A Contactor for WPG4484115RKB1 — 24V Coil | Ships Today

SKU: WPG4484115RKB1 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM contactor (part number 1173690) is the factory-specified single-pole, 40-amp switching relay for the ICP / Tempstar / Heil WPG4484115RKB1 unit. Energized by the 24-volt control circuit, the contactor closes its high-amperage contacts to power the compressor and condenser fan when the thermostat calls for cooling. Over time the contacts pit, weld, or burn, causing the system to fail to start, chatter, or run continuously. Replacing a worn contactor restores clean, reliable switching and protects the costly compressor downstream.

Specifications

Spec Value
OEM Part Number 1173690
Type Definite Purpose Contactor
Poles 1 (Single-Pole)
Contact Rating 40 Amps
Coil Voltage 24 VAC
Brand ICP / Tempstar / Heil
Fits Model WPG4484115RKB1
Fitment OEM Direct Replacement

Compatibility

Direct-fit OEM replacement for the ICP / Tempstar / Heil WPG4484115RKB1 package unit. Confirm the pole count, amp rating, and 24V coil match your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker. Verify zero voltage with a multimeter before working.
  2. Access — Remove the service panel covering the electrical compartment.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each lead exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in cleanly with no chatter.

Signs You Need a Replacement

  • Buzzing, chattering, or humming from the contactor
  • Pitted, blackened, or welded contacts
  • Compressor won't start on a cooling call
  • Unit runs continuously even when satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG4484115RKB1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG4484115RKB1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG4484115RKB1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online