This OEM contactor (part #1173690) is the 1-pole, 40 amp, 24V-coil relay that switches line power to the compressor and condenser fan in the ICP/Tempstar/Heil WPG4484115LKA1. When the thermostat calls for cooling, 24V energizes the coil and pulls the contacts closed, delivering 208/230V to the outdoor unit. Over time the contacts pit, burn, or weld, and the coil can open or stick, causing the compressor to run continuously, chatter, or fail to start. Typical failure signs include a buzzing or chattering contactor, pitted or melted contacts, and an outdoor unit that won't shut off or won't energize.

Specifications

Spec Value
Part Number 1173690
Type Definite Purpose Contactor
Brand ICP
Poles 1-Pole
Amperage 40A
Coil Voltage 24V
Fitment OEM

Compatibility

Direct OEM replacement for ICP, Tempstar, Heil, and Comfortmaker units built around the WPG4484115LKA1 platform. Confirm pole count, amp rating, and 24V coil against your original contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser control-box service panel.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove — Label and disconnect the wires, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor, land the line and load conductors, and connect the 24V coil leads per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the unit starts.

Signs You Need a Replacement

  • Loud buzzing or chattering at the contactor
  • Pitted, burnt, or welded contacts
  • Outdoor unit won't start or won't shut off
  • Coil reads open or contactor fails to pull in on a 24V call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG4484115LKA1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG4484115LKA1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG4484115LKA1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online