Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 40A Contactor for WPG4484090LKA1 — 24V Coil | Ships Today
ICP

ICP 1-Pole 40A Contactor for WPG4484090LKA1 — 24V Coil | Ships Today

SKU: 1173690 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM single-pole (1-pole) 40 amp contactor with a 24V coil (part number 1173690) for the ICP Tempstar Heil WPG4484090LKA1. The contactor is the high-voltage relay that switches line power to the compressor and condenser fan motor. When the thermostat calls for cooling, 24V energizes the coil, pulling the contacts closed to send line voltage to the outdoor unit. Over time the contacts pit, burn, and weld from arcing, while the coil can fail open. Symptoms of a bad contactor include a humming or chattering outdoor unit, a compressor that won't start, or contacts that stick closed so the unit runs continuously.

Specifications

Spec Value
Part Number 1173690
Type Definite Purpose Contactor, Single Pole
Brand ICP (Tempstar / Heil)
Poles 1
Contact Rating 40A
Coil Voltage 24V
Fit OEM direct replacement

Compatibility

Direct-fit OEM replacement for the ICP Tempstar Heil WPG4484090LKA1 and equivalent ICP-built Tempstar, Heil, Comfortmaker, and Arcoaire units that use the 1-pole 40A 24V contactor 1173690. Confirm pole count, 40A rating, and 24V coil on the existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker and verify zero voltage with a multimeter across the contactor terminals.
  2. Access — Remove the service panel to expose the contactor in the control area.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect line, load, and coil wiring exactly per your photos.
  6. Test — Restore power, call for cooling, and confirm the coil pulls the contacts in and the compressor/fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but won't start.
  • Burned, pitted, or welded contacts.
  • Contacts stick closed and the unit runs nonstop.
  • 24V coil reads open or fails to pull the contacts in.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG4484090LKA1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG4484090LKA1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG4484090LKA1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR