Overview

This genuine ICP definite-purpose contactor (OEM part 1173690) is the high-current switch that powers the compressor and condenser fan on the WPG3484115RKC1 package unit. It is a single-pole device rated for 40 amps with a 24V coil. When the thermostat calls for cooling, the control board energizes the 24V coil, pulling the contacts closed to send line voltage to the compressor and fan. Over time the contacts pit, arc, and burn from constant switching — leading to chattering, a buzzing coil, or contacts that weld closed and run the compressor continuously. A clean OEM-spec contactor restores reliable, quiet switching and protects the costly compressor from voltage problems.

Specifications

Spec Value
Part Number 1173690
Type Definite-purpose contactor
Brand ICP (Tempstar / Heil / Comfortmaker)
Poles 1 (single-pole)
Contact Rating 40 A
Coil Voltage 24 V
Fitment OEM direct replacement
Model WPG3484115RKC1

Compatibility

Direct-fit replacement for the ICP Tempstar Heil WPG3484115RKC1 package unit, matching the original mounting bracket, 40A line terminals, and 24V coil connections. Confirm pole count and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control service panel.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove — Transfer wires one at a time, or label each, then unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect every line, load, and coil wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Loud chattering or buzzing when the system calls for cooling
  • Pitted, burned, or welded contacts visible on inspection
  • Compressor and fan won't start despite a good 24V coil signal
  • Compressor runs nonstop because the contacts stay closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG3484115RKC1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG3484115RKC1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG3484115RKC1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online